AirBench FN

AirBench FN is a heavy duty downdraught bench, for extraction of dust and fumes from hazardous processes. FN is constructed from fully welded 2mm steel panels, powder coated grey as standard. The surface is constructed from 3mm perforated steel plate, also powder coated grey.
AirBench FN - With access door open AirBench FN is designed for continuous, production level duties in industrial environments, and is suitable for surface loads up to 100kg. AirBench FN - Heavy Duty Downdraught Bench
Filters are positively clamped against soft rubber seals; filters can be quickly accessed via the top for cleaning. Replacement is via removal of the front cover. Filter changes can be accomplished in minutes.

All units are supplied with an integral 240v fanset with IP56 motor enclosure; on/off switch (optional speed control); 3m mains lead; and fused plug. A precision filter pressure loss gauge is fitted as standard on all units to allow real-time monitoring of filter condition.

Performance, pricing, and filter selections are generally identical to comparable EX and FP models.

Specifications may vary; contact us to discuss the correct model and filter selection for your application.

Dimensions and Models FN Range

Width
Depth
Height
Model No
  670 675 840 FN066784
1270 675 840 FN126784
1870 675 840 FN186784
1270 975 840 FN129784
1870 975 840 FN189784

Request Information

Sorry, we've had to temporarily disable our on-line form because someone is interfering with it. You can request information by emailing us at:

sales@airbench.com 

Related Downloads


Construction Specifications FN Models

  • Body: Welded, formed 2mm mild steel panels; powder coated grey after fabrication.
  • Surface: Perforated 3mm mild steel; powder coated grey after fabrication
  • Filter housing: Spring-clamped against purpose made soft rubber seals
  • Filter access: Via hinged front cover for removal; access available via surface for cleaning.
  • Power supply requirements: 240V single phase as standard. 170w - 1100w dependant on model. 110V version available.
  • Mains connection: 3m mains lead supplied as standard
  • Filter Monitoring: Precision differential pressure gauge fitted as standard.

Applications FN Range

AirBench FN is available with the following standard filter configurations:
  • A - Dust, No Sparks
  • H - Fine Dust, No Sparks
  • B - Very Fine Dust
  • L - HEPA Filtration
  • E - Low Volume Fume
  • C - Dust With Some sparks
Use the menu on the right for further information about specific filter configurations.

Accessories

We supply a full range of accessories including:
  • Castors
  • Remote fans and ducting
  • Electronic speed control
  • Enclosures
  • Spare filters and alternative filter sets
  • Hours run meters
  • Audible low flow alarm