| AirBench FN-E is specified for extraction of organic and non-organic fume in relatively low volumes and at non-hazardous levels. Sample applications include adhesives, solvents, conformal coatings, airbrushing, cleaning fluids, and spraypainting. Certain substances cannot be filtered by standard grade carbon filtration; see our carbon effectiveness guide here. For these applications, we recommend our 'R' configuration - use the menu on the left to find out more. |
Construction Specifications |
|
|
|
Dimensions and Models |
|||
|
Width
|
Depth
|
Height
|
Model No
|
| 670 | 675 | 840 | FN066784E |
| 1270 | 675 | 840 | FN126784E |
| 1870 | 675 | 840 | FN186784E |
| 1270 | 975 | 840 | FN129784E |
| 1870 | 975 | 840 | FN189784E |
Pre-filter
|
| Type: EU4/50 Description: 50mm deep V-section pleated panel Construction: Galvanised steel frame. Fully bonded media. Grade: EU4 (approx 95% effective at 5 microns) Estimated life: 6-12 months dependant on level of use. |
Main filter
|