HCL Acid Fume Hazards: Is Hydrochloric Acid Dangerous?

The usefulness of HCL comes with specific hazards when the acid or hydrogen chloride fumes generated during handling are not controlled properly. Fume extractions systems can form part of an effective approach to controlling airborne contaminants.

HCL Acid Fume Hazards

© chalermphon_tiam / Shutterstock.com

 

Is hydrochloric acid dangerous?

The UK Health and Safety Executive identifies hydrogen chloride, including gas and aerosol mists associated with hydrochloric acid, as requiring workplace exposure limits. Under COSHH legislation, employers must prevent or adequately control exposure to hazardous substances.

The current UK workplace limits distinguish between long-term and short-term exposure. Long-term, the limit is 1 part per million, which is the equivalent to 2mg per cubic metre of air, averaged over an eight-hour working day. There is also a short-term exposure limit of 5 parts per million, equivalent to 8mg per cubic metre of air, measured over a 15-minute reference period.

 

Understanding HCL acid hazards in the workplace

The principal concern is inhalation. Hydrochloric acid can release hydrogen chloride into the surrounding atmosphere, particularly where concentrated solutions are transferred, agitated, heated or exposed to conditions that promote fume generation. Processes such as metal pickling and surface treatment can require carefully designed ventilation and local exhaust ventilation.

Exposure can occur when fumes escape from an open process tank, during filling and transfer operations, through inadequate tank ventilation or when an extraction system fails to capture contaminants effectively.

Due to the corrosive nature of hydrochloric acid fumes, they may attack unsuitable materials used in tanks, fittings, ductwork and associated equipment.

 

Why controlling HCL exposure matters

When considering the safety of HCL in the workplace, controlling the concentration in the worker’s breathing zone is particularly important. A process that is closed under normal conditions may present little routine exposure, but an open pickling tank or manual transfer operation can create a more hazardous exposure profile.

General ventilation may help manage background contamination, but it doesn’t necessarily prevent a worker from encountering concentrated exposure close to source. Local exhaust ventilation is intended to capture contaminants before they disperse into the wider workplace.

 

The role of fume extraction

Fume extractions systems can help control HCL fumes at source, but their effectiveness depends on how well the system is matched to the application: an extraction hood placed too far from a tank or process may allow fumes to escape.

The AirBench industrial fume extraction range includes downdraught benches, cross-draught systems and other configurations designed around different workplace applications. Filtration should be selected accordingly.

An acid fume extraction system should be designed around the actual process, rather than selected as a generic ventilation product. The material used throughout the contaminated airflow path is an important consideration. Hydrochloric acid fumes are corrosive, so components exposed to them need to be compatible with the chemical conditions.

Polypropylene and other corrosion-resistant materials are commonly considered for acid extraction applications, although material suitability should always be confirmed against the actual chemical concentration, temperature and operating conditions.

The system needs sufficient capacity to capture HCL fumes under the operating conditions of the process. Depending on the application, extracted air may require appropriate filtration, treatment or scrubbing before discharge. Changes in ductwork, pressure losses, capture geometry and airflow distribution can all affect performance.

A properly engineered system should be commissioned and subsequently maintained so its effectiveness can be demonstrated.

 

Signs that extraction may need reviewing

Changes in the process, visible fumes escaping from the capture area, corrosion of extraction components or changes in production volumes can all indicate that an existing system may need to be reassessed. Unusual odours or complaints of irritation should also be investigated. Regular inspection and performance checks can help identify issues before they affect the level of control provided.

 

Is your existing HCL control adequate?

If an existing system no longer reflects the requirements of the process, a more detailed assessment can help determine whether it needs to be adapted or replaced. This provides an opportunity to consider the extraction design alongside current production methods, working practices and future changes to the process.

More Latest

WWII Behind the Mask

WWII: Behind the Mask

Find out more
Extraction Solutions for Reactive Metal Dust: When Is It Required

Extraction Solutions for Reactive Metal Dust

Find out more
Controlling Fine Plastic Dust Extraction Systems for Plastic Fabrication

Controlling Fine Plastic Dust: Extraction Systems for Plastic Fabrication

Find out more
Understanding the Health Risks of Acrylic Dust & Fumes

Understanding the Health Risks of Acrylic Dust & Fumes

Find out more

Why choose AirBench?

AirBench Ltd are the UK’s leading manufacturer of downdraught benches and cross draught extraction systems. We have more than 10,000 extraction systems in service in the UK and overseas. Along with our range of coolant mist filters and air cleaning systems, we are actively helping businesses across many industries solve their workplace dust and fume issues.

 

If you'd like to try an AirBench product for FREE simply book a demo and we'll bring one to you.